Skip to main content

Table 2 Results of the incremental exercise tests at HA and SL

From: Minute ventilation and heart rate relationship for estimation of the ventilatory compensation point at high altitude: a pilot study

 

HA

SL

P value

SpO2peak (%)

72.8 ± 7.3

98 ± 1.4

<0.001

WRpeak (W)

138 ± 26

208 ± 44

<0.01

V ˙ O 2 peak (ml/min)

1,690 ±533

2,227 ± 511

<0.01

V ˙ CO 2 peak (ml/min)

2,060 ± 570

2,820 ± 780

<0.01

V ˙ Epeak (l/min)

123.4 ± 33.3

91.3 ± 28.6

<0.01

θL (ml/min)

1,015 ± 222

1,302 ± 241

<0.01

HRpeak (bpm/min)

147 ± 13

168 ± 12

<0.001