Skip to main content

Table 1 Change in hand and forearm blood flow during thermal stimulation of the face, hand and thigh.

From: Cutaneous thermosensitivity differences among the face, hand or thigh appear not to exist for skin blood flow during normothermic states

Treated site

Hand and forearm blood flow changes (mL.100 mL tissue-1.min-1)

 

Heating

Cooling

Face

2.73 (SD 1.65)

-1.54 (SD 1.49)

Hand

3.40 (SD 2.98)

-1.59 (SD 1.00)

Thigh

1.93 (SD 1.81)

-2.17 (SD 2.02)