Skip to main content

Table 1 Mean temperature difference of each insulation system tested

From: Measurements of rates of cooling of a manikin insulated with different mountain rescue casualty bags

Insulation system

Initial mean water temperature (T 0, °C)

Final mean water temperature (T 130 min, °C)

Mean temperature difference (T 0T 130 min, °C)

Control

41.63

29.43

12.20

Vacuum mattress and Pertex© blanket

41.70

38.53

3.17

Vacuum mattress, Pertex© blanket and Wiggy bag

41.70

38.50

3.20

Wiggy bag

41.70

37.50

4.20

ME casualty bag

41.70

37.43

4.27

Blizzard bag

41.70

35.63

5.37

Plastic orange survival bag

41.70

32.17

9.53