- Meeting abstract
- Open access
- Published:
Cranial cooling during firefighting recovery effects on physiological and perceptual strain
Extreme Physiology & Medicine volume 4, Article number: A1 (2015)
Introduction
We performed a firefighting simulation of repeated work-rest bouts while wearing fire-fighting ensemble (FFE) and self-contained breathing apparatus (SCBA) in the heat, removing the helmet and SCBA during recovery and comparing cranial cooling (CC) versus passive (CON) exposure. We hypothesized that CC would better counteract heat storage compared to passive cooling.
Methods
Eleven males (mean (SD), 30.9 (9.2) y, 49.5 (5.1) mL.kg-1.min-1 ) performed two trials consisting of 2 × 20 min bouts of treadmill walking (5.6 km.h-1, 4 % incline) in 35 °C and 60 % relative humidity while wearing full FFE and SCBA, with 20 min passive recovery between each exercise bout. During recovery, participants sat in the chamber and removed gloves, helmet, fire hood, and SCBA, but the jacket remained buttoned up. For CC, a close-fitting custom liquid-perfused hood pumped 13 °C water at a rate of ~500 mL.min-1 through the head and neck regions. For CON, participants performed the same recovery but the hood was not perfused to simulate wearing the fire hood and helmet. Rectal temperature (Tre), heart rate (HR), and ventilation () were continuously recorded throughout exercise and recovery, while subjective ratings of perceived exertion (RPE), thermal comfort (TC), and breathing stress (BrS) were obtained every 4-5 min during exercise and recovery. Significance was set at p = 0.05.
Results
All participants successfully completed the first exercise bout, with no differences in any variable prior to the experimental recovery manipulation. Rectal temperature rose in both CC (0.11 ± 0.19 °C,) and CON (0.26 ± 0.15 °C) during Rest, with non-significant interaction between conditions (p = 0.076). During Rest, neck temperature was lower in CC compared to CON from 4 min (CC: 35.73 ± 3.28 °C, CON: 37.66 ± 1.35 °C, p = 0.025) until the end (CC: 33.06 ± 4.70 °C, CON: 36.85 ± 1.63 °C, p = 0.014). HR significantly decreased over recovery in both CC and CON, with no significant differences between conditions. Perceptually, TC was significantly lower in CC at 5 min, 10 min, 15 min, and 20 min time points during the Rest period compared to CON. There were no significant differences in tolerance times (voluntary termination or Tre = 40 °C) between CC (16.55 (1.14) min) and the CON (16.60 (1.31) min). Tre was not significantly different at the start (CC: 38.3 (0.40) °C, CON: 38.40 (0.16) °C) and at the end (CC: 38.82 (0.23) °C, CON: 39.07 (0.22) °C) of Exercise2. HR was not significantly different at the start (CC: 149 (17.6) b.min-1, CON: 157 (15.6) b.min-1) and at the end (CC: 162 (18.76) b.min-1, CON: 174 (12.13) b.min-1) of Exercise2. Total VE during Exercise2 was similar between CC (1146.3 (331.9) L) and CON (1173.3 (307.0) L) as was BrS and RPE.
Discussion
The face and head has a high alliesthesial thermosensitivity [1], but Tyler et al. proposed [2] that a sufficient thermal strain threshold was necessary for neck cooling to be effective. However, our high rate of heat stress potentially overwhelmed any cooling benefit from CC, as any attenuation in physiological and perceptual responses was transient. Thermal hyperpnea was also not alleviated by CC, with no effect on ventilatory demands and air usage. While head and neck cooling during recovery may attenuate thermal discomfort, it is not an effective strategy to decrease the rate of physiological strain or extend tolerance time during heavy exercise in the heat when recovery is performed while largely encapsulated.
References
Tyler CJ, Wild P, Sunderland C: Practical neck cooling and time-trial running performance in a hot environment. Eur J Appl Physiol. 2010, 110: 1063-1074. 10.1007/s00421-010-1567-7.
Cotter JD, Taylor NAS: The distribution of cutaneous sudomotor and alliesthesial thermosensitivity in mildly heat-stressed humans: An open-loop approach. J Physiol. 2005, 565: 335-345. 10.1113/jphysiol.2004.081562.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Cheung, S.S., Wallace, P.J., Masbou, A. et al. Cranial cooling during firefighting recovery effects on physiological and perceptual strain. Extrem Physiol Med 4 (Suppl 1), A1 (2015). https://doi.org/10.1186/2046-7648-4-S1-A1
Published: