- Meeting abstract
- Open Access
- Published:
An eye on hydration: efficacy of intraocular pressure to measure body water deficit
Extreme Physiology & Medicine volume 4, Article number: A139 (2015)
Introduction
Current best-practice hydration assessment include techniques involving isotope dilution to estimate total body water; osmolality of blood, saliva, or urine; specific gravity or colour of urine; and changes in body mass. These techniques are either prohibitively expensive, invasive, require clinical laboratory equipment, rely on a non-dehydrated baseline criterion, or on body fluids that are compromised in a dehydrated individual. In this study we report on the capability of intraocular pressure (the pressure within the eye; IOP), to assess dehydration. IOP can be measured quickly and accurately using a handheld device (tonometer), therefore offering portability, and sterility, and can be used by anyone following minimal training [1].
Methods
Twelve healthy males (mean (SD): age 24 (2.3) yr, height 178 (6.1) cm, weight 75 (6.6) kg, VO2max 56 (4.4) mL.kg-1.min-1, sum of eight skinfolds 75 (29) mm) completed two trials each comprising 150 minutes of treadmill walking (5 km,h-1 and 1 % grade), in a hot and dry environment (40 °C and 20 % relative humidity). One trial was undertaken with fluid (water) replacement to minimise body mass changes (EUH) and one without fluid to maximise dehydration (DEH). The order of the trials was randomized and the trial days were separated by a minimum of seven days. At baseline and at 30 minute intervals participants were removed from the hot and humid environment into a temperate air-conditioned laboratory to have IOP, nude body mass and serum osmolality assessed.
Discussion
IOP was progressively reduced during a period of exercise causing dehydration, but remained relatively stable if hydration was maintained. The large within and between individual variation in IOP meant that an absolute IOP value could not be identified to provide a criterion cut-off to represent a dehydrated condition. However utilising a change from a euhydrated baseline, delta IOP was significantly different between the conditions at increasing levels of body mass loss and serum osmolality.
Conclusion
The evidence suggests that IOP is influenced by hydration status, likely due to the effect of a rise in blood osmolality on the rate of formation of aqueous humour.
References
Hunt A, Feigl B, Stewart I: The intraocular pressure response to dehydration: a pilot study. Eur J Appl Physiol. 2012, 112 (5): 1963-1966. 10.1007/s00421-011-2143-5.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Stewart, I., Costello, J. & Dias, B. An eye on hydration: efficacy of intraocular pressure to measure body water deficit. Extrem Physiol Med 4 (Suppl 1), A139 (2015). https://doi.org/10.1186/2046-7648-4-S1-A139
Published:
DOI: https://doi.org/10.1186/2046-7648-4-S1-A139
Keywords
- Intraocular Pressure
- Aqueous Humour
- Total Body Water
- Serum Osmolality
- Treadmill Walking